The Journal of Minimally Invasive Surgery :eISSN 2234-5248   pISSN 2234-778X

Download original image
Fig. 2. Calculated length of fascia incision for SITPLA using 5 mm-trocar with a diameter of 7.7 mm. Expected incision size, (7.7π+15.4)/2≒ 19.79 mm; SITPLA, Single-incision two-port laparoscopic appendectomy.
Journal of Minimally Invasive Surgery 2019;22:11~17 https://doi.org/10.7602/jmis.2019.22.1.11