Video/Multimedia Article

Split Viewer

Journal of Minimally Invasive Surgery 2019; 22(4): 181-183

Published online December 15, 2019

https://doi.org/10.7602/jmis.2019.22.4.181

© The Korean Society of Endo-Laparoscopic & Robotic Surgery

Initial Clinical Experience of Pure Single-Incision Robotic Right Hemicolectomy with da Vinci SP Platform

Gyoung Tae Noh , M.D., Myunghyun Han , M.D., Soon Sup Chung , M.D., Ph.D., Ryung-Ah Lee , M.D., Ph.D., Kwang Ho Kim , M.D., Ph.D.

Department of Surgery, Ewha Womans University College of Medicine, Seoul, Korea

Correspondence to : Kwang Ho Kim Department of Surgery, Ewha Womans University College of Medicine, 260 Gonghang-daero, Gangseo-gu, Seoul 07804, Korea Tel: +82-2-6986-4689 Fax: +82-2-6986-4689 E-mail: eastgate@ewha.ac.kr ORCID: https://orcid.org/0000-0003-0928-6669

Video presentation at the 71th Annular Congress of Korean Surgical Society, Seoul, Korea, Oct. 31 to Nov. 2, 2019.

Received: November 29, 2019; Revised: December 8, 2019; Accepted: December 9, 2019

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

The da Vinci SP Surgical System (dVSP; Intuitive Surgical, Sunnyvale, CA, USA) was introduced to perform pure single-incision surgery in 2018. This new surgical platform demonstrated favorable performance compared with the positive aspect of single-incision laparoscopic surgery and robot surgery. To date, its use has mainly been in urological and gynecological procedures. We report a case of successful robotic single-incision right hemicolectomy for cecal cancer with the dVSP.

Keywords Robotic surgery, da Vinci SP, Single-incision, Right hemicolectomy

Since Weber et al.1 reported the first procedure of robotic colon resection in 2002, robotic surgery had been verified as a safe and effective procedure for colorectal disease, with the advantage of stable and magnified three-dimensional view, increased degrees of freedom of devices, enhanced dexterity, superior ergonomic design, and a shorter learning curve.24 In 2018, Intuitive Surgical launched the da Vinci SP surgical system (dVSP). It was developed as a novel robotic platform to perform robotic single-incision surgery. It has double articulating joints in robotic instruments and articulating endoscope permitting flexible movement. All robotic instruments and endoscope are inserted through a cylindrical single port with a diameter of 2.5 cm.

To date, its use has mainly been in urological and gynecological procedures. Herein, we report a case of cecal cancer, which was successfully operated with the dVSP.

Patient

A 65-year-old male diagnosed with cecal cancer on the screening colonoscopy, which showed a 2 cm sized fungating mass in cecum. Biopsy revealed it as a moderately differentiated adenocarcinoma. On the following computed tomography, no definite cecal wall thickening, metastatic lymph node or distant metastasis was identified, and a single-incision robotic right hemicolectomy with dVSP was planned. Due to the retrospective nature of this report and the use of an anonymized patient data, requirements for informed consent were waived by the IRB.

Installation and docking

The patient underwent standard bowel preparation the day before surgery and received prophylactic antibiotics before incision. A vertical midline incision, 35~40 mm in length, separating the umbilicus 10 mm away from the upper and lower margins of the umbilicus. An access port was made using a standard wound retractor of SurgiTractor® (SurgiCore, Gwangju, Korea) and size 6, non-latex, powder-free sterile glove. The surgical glove was fixed to the outer ring of the wound retractor. A 25 mm multichannel robotic trocar and two accessory assistant trocars (12 mm and 5 mm) were inserted through fingers of the surgical glove after cutting its fingertips. After achieving pneumoperitoneum with insufflations of carbon dioxide to 12 mmHg, the patient was placed in Trendelenberg position at 15° and tilted left side down. After patients’ positioning, laparoscopic exploration was undertaken using laparoscopic instruments through robotic and assistant ports. After completing laparoscopic exploration, the robot was docked with a 0° flexible endoscope, monopolar curved scissors, bipolar grasper, and Cadiere forceps. All robotic endoscope and instruments were inserted through a 25 mm single robotic trocar.

Surgical procedure

Mobilization of the ascending colon and mesocolon was first performed via an inferior approach. The peritoneal reflection of the small bowel mesentery was incised. Dissection into the surgical plane above Gerota’s fascia was performed to mobilize the entire ascending colon mesentery from the retroperitoneal structures. The duodenum and pancreatic head were exposed, with the hepato-duodenal ligament excised, and takedown of the hepatic flexure in a lateral to medial fashion. Lymphadenectomy was performed along the superior mesenteric vessels, with individual exposure and ligation of the ileocolic, right colic, and right branch of middle colic vessels at their origin from the superior mesenteric artery, vein, and middle colic trunk. The gastrocolic trunk was exposed and the colonic branch was ligated while preserving the pancreatic branches. Omentectomy was performed at the level inferior to the gastro-epiploic vessels and the transverse colon was mobilized from the omentum. Subsequently, the mesocolon of the transverse colon and the mesentery of the ileum were divided until the desired resection margins were achieved. Bowel resection and anastomosis were performed extracorporeally. After releasing the robot from docking and separating the glove from the wound retractor, mobilized bowel was exteriorized through an umbilical incision, and stapled ileocolic end-to-side anastomosis was performed.

Peri- and postoperative outcomes

The procedure was successfully completed using a pure single-incision approach. Operative time, docking time, and console time were 355 minutes, 15 minutes, and 263 minutes, respectively. Estimated blood loss was 100.0 ml. Intraoperative complication or conversion to laparoscopic or open surgery was not occurred. On the pathologic report, 1.9 cm sized fungating mass infiltrating till proper muscle of cecum (pT2) was identified. Distance from tumor to the proximal and distal resection margins were 6.5 cm and 18 cm, respectively. Twenty-three lymph nodes were harvested and no metastatic lymph node was identified (pN0). The patient recovered without any complication and was discharged to home at postoperative day 6. Patient passed gas and resumed a soft diet on postoperative day 3.

The dVSP was designed for pure single-incision surgery with three double-jointed instruments and articulating endoscope inserted through one entry point. Double-jointed instruments enable the creation of adequate triangulation for surgical procedures. The single port enables 360° anatomical access without port placement modification, thus overcoming the abdominal quadrant limitation of previous robotic platforms. To apply this new platform to colorectal surgery, we adopted a glove-port to secure a distance from the port to the surgical target. To achieve adequate triangulation with multi-joint robotic instruments, the cannula tip should be >12 cm from the surgical target to permit proximal joint passing the cannula tip and articulating. Using this glove-port and making the cannula tip to be outside of the abdominal cavity, we were able to secure the distance to the surgical target, especially for lymphadenectomy around the central vessels under trans-umbilical port placement, thus maximizing the cosmetic effect.

In the present report, the dVSP demonstrated favorable performance compared with positive aspect of single-incision laparoscopic surgery and robot surgery. There was minimal collision among instruments and endoscope compared to single-incision laparoscopic surgery while maintaining the advantages of robotic surgery such as better three-dimensional view, dexterity, and ergonomics. The peri- and postoperative results were also favorable. Considering its initial application for right hemicolectomy, the operation time was acceptable. Free location of robotic cart around operating table could be an advantage to shorten the docking time compared to previous robotic system models which required fixed location and angle to the operating table. Estimated blood loss during surgery and duration of postoperative hospital stay, time to first flatus and soft diet was comparable to previous reports of laparoscopic or robotic colorectal surgery.57 Regarding pathologic outcomes, the number of retrieved lymph nodes and status of resection margin were acceptable. The cosmetic result was satisfactory with a transumbilical incision, which was essential to extract the surgical specimen for colorectal surgery and visible scarring was minimal.

In summery, the dVSP is feasible and safe to perform single-incision robotic right hemicolectomy. It can maximize cosmetic effect while maintaining surgical principle of right hemicolectomy. Accumulation of data might confirm the validity of this surgical platform.

Conceptualization: GRN, GHK. Formal analysis: GTN, MHH, SSC, RAL, KHK. Methodology: GTN, MHH, SSC, RAL, KHK. Writing-original draft: GTN, KHK. Writing-review and editing: GTN, SSC, RAL, KHK.

  1. Weber PA, Merola S, Wasielewski A, Ballantyne GH. Telerobotic-assisted laparoscopic right and sigmoid colectomies for benign disease. Dis Colon Rectum 2002;45:1689-1696.
    Pubmed CrossRef
  2. Balch GC. Emerging role of laparoscopic and robotic surgery for rectal cancers. Ann Surg Oncol 2009;16:1451-1453.
    Pubmed CrossRef
  3. Pigazzi A, Garcia-Aguilar J. Robotic colorectal surgery: for whom and for what?. Dis Colon Rectum 2010;53:969-970.
    Pubmed CrossRef
  4. Rashid TG, Kini M, Ind TEJ. Comparing the learning curve for robotically assisted and straight stick laparoscopic procedures in surgical novices. Int J Med Robot 2010;6:306-310.
    Pubmed CrossRef
  5. Rondelli F, Balzarotti R, Villa F, et al. Is robot-assisted laparoscopic right colectomy more effective than the conventional laparoscopic procedure? A meta-analysis of short-term outcomes. Int J Surg 2015;18:75-82.
    Pubmed CrossRef
  6. Kim MJ, Park SC, Park JW, et al. Robot-assisted Versus Laparoscopic Surgery for Rectal Cancer: A Phase II Open Label Prospective Randomized Controlled Trial. Ann Surg 2018;267:243-251.
    Pubmed CrossRef
  7. Park EJ, Cho MS, Baek SJ, et al. Long-term oncologic outcomes of robotic low anterior resection for rectal cancer: a comparative study with laparoscopic surgery. Ann Surg 2015;261:129-137.
    Pubmed CrossRef

Article

Video/Multimedia Article

Journal of Minimally Invasive Surgery 2019; 22(4): 181-183

Published online December 15, 2019 https://doi.org/10.7602/jmis.2019.22.4.181

Copyright © The Korean Society of Endo-Laparoscopic & Robotic Surgery.

Initial Clinical Experience of Pure Single-Incision Robotic Right Hemicolectomy with da Vinci SP Platform

Gyoung Tae Noh , M.D., Myunghyun Han , M.D., Soon Sup Chung , M.D., Ph.D., Ryung-Ah Lee , M.D., Ph.D., Kwang Ho Kim , M.D., Ph.D.

Department of Surgery, Ewha Womans University College of Medicine, Seoul, Korea

Correspondence to:Kwang Ho Kim Department of Surgery, Ewha Womans University College of Medicine, 260 Gonghang-daero, Gangseo-gu, Seoul 07804, Korea Tel: +82-2-6986-4689 Fax: +82-2-6986-4689 E-mail: eastgate@ewha.ac.kr ORCID: https://orcid.org/0000-0003-0928-6669

Video presentation at the 71th Annular Congress of Korean Surgical Society, Seoul, Korea, Oct. 31 to Nov. 2, 2019.

Received: November 29, 2019; Revised: December 8, 2019; Accepted: December 9, 2019

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

The da Vinci SP Surgical System (dVSP; Intuitive Surgical, Sunnyvale, CA, USA) was introduced to perform pure single-incision surgery in 2018. This new surgical platform demonstrated favorable performance compared with the positive aspect of single-incision laparoscopic surgery and robot surgery. To date, its use has mainly been in urological and gynecological procedures. We report a case of successful robotic single-incision right hemicolectomy for cecal cancer with the dVSP.

Keywords: Robotic surgery, da Vinci SP, Single-incision, Right hemicolectomy

INTRODUCTION

Since Weber et al.1 reported the first procedure of robotic colon resection in 2002, robotic surgery had been verified as a safe and effective procedure for colorectal disease, with the advantage of stable and magnified three-dimensional view, increased degrees of freedom of devices, enhanced dexterity, superior ergonomic design, and a shorter learning curve.24 In 2018, Intuitive Surgical launched the da Vinci SP surgical system (dVSP). It was developed as a novel robotic platform to perform robotic single-incision surgery. It has double articulating joints in robotic instruments and articulating endoscope permitting flexible movement. All robotic instruments and endoscope are inserted through a cylindrical single port with a diameter of 2.5 cm.

To date, its use has mainly been in urological and gynecological procedures. Herein, we report a case of cecal cancer, which was successfully operated with the dVSP.

PROCEDURES

Patient

A 65-year-old male diagnosed with cecal cancer on the screening colonoscopy, which showed a 2 cm sized fungating mass in cecum. Biopsy revealed it as a moderately differentiated adenocarcinoma. On the following computed tomography, no definite cecal wall thickening, metastatic lymph node or distant metastasis was identified, and a single-incision robotic right hemicolectomy with dVSP was planned. Due to the retrospective nature of this report and the use of an anonymized patient data, requirements for informed consent were waived by the IRB.

Installation and docking

The patient underwent standard bowel preparation the day before surgery and received prophylactic antibiotics before incision. A vertical midline incision, 35~40 mm in length, separating the umbilicus 10 mm away from the upper and lower margins of the umbilicus. An access port was made using a standard wound retractor of SurgiTractor® (SurgiCore, Gwangju, Korea) and size 6, non-latex, powder-free sterile glove. The surgical glove was fixed to the outer ring of the wound retractor. A 25 mm multichannel robotic trocar and two accessory assistant trocars (12 mm and 5 mm) were inserted through fingers of the surgical glove after cutting its fingertips. After achieving pneumoperitoneum with insufflations of carbon dioxide to 12 mmHg, the patient was placed in Trendelenberg position at 15° and tilted left side down. After patients’ positioning, laparoscopic exploration was undertaken using laparoscopic instruments through robotic and assistant ports. After completing laparoscopic exploration, the robot was docked with a 0° flexible endoscope, monopolar curved scissors, bipolar grasper, and Cadiere forceps. All robotic endoscope and instruments were inserted through a 25 mm single robotic trocar.

Surgical procedure

Mobilization of the ascending colon and mesocolon was first performed via an inferior approach. The peritoneal reflection of the small bowel mesentery was incised. Dissection into the surgical plane above Gerota’s fascia was performed to mobilize the entire ascending colon mesentery from the retroperitoneal structures. The duodenum and pancreatic head were exposed, with the hepato-duodenal ligament excised, and takedown of the hepatic flexure in a lateral to medial fashion. Lymphadenectomy was performed along the superior mesenteric vessels, with individual exposure and ligation of the ileocolic, right colic, and right branch of middle colic vessels at their origin from the superior mesenteric artery, vein, and middle colic trunk. The gastrocolic trunk was exposed and the colonic branch was ligated while preserving the pancreatic branches. Omentectomy was performed at the level inferior to the gastro-epiploic vessels and the transverse colon was mobilized from the omentum. Subsequently, the mesocolon of the transverse colon and the mesentery of the ileum were divided until the desired resection margins were achieved. Bowel resection and anastomosis were performed extracorporeally. After releasing the robot from docking and separating the glove from the wound retractor, mobilized bowel was exteriorized through an umbilical incision, and stapled ileocolic end-to-side anastomosis was performed.

Peri- and postoperative outcomes

The procedure was successfully completed using a pure single-incision approach. Operative time, docking time, and console time were 355 minutes, 15 minutes, and 263 minutes, respectively. Estimated blood loss was 100.0 ml. Intraoperative complication or conversion to laparoscopic or open surgery was not occurred. On the pathologic report, 1.9 cm sized fungating mass infiltrating till proper muscle of cecum (pT2) was identified. Distance from tumor to the proximal and distal resection margins were 6.5 cm and 18 cm, respectively. Twenty-three lymph nodes were harvested and no metastatic lymph node was identified (pN0). The patient recovered without any complication and was discharged to home at postoperative day 6. Patient passed gas and resumed a soft diet on postoperative day 3.

DISCUSSION

The dVSP was designed for pure single-incision surgery with three double-jointed instruments and articulating endoscope inserted through one entry point. Double-jointed instruments enable the creation of adequate triangulation for surgical procedures. The single port enables 360° anatomical access without port placement modification, thus overcoming the abdominal quadrant limitation of previous robotic platforms. To apply this new platform to colorectal surgery, we adopted a glove-port to secure a distance from the port to the surgical target. To achieve adequate triangulation with multi-joint robotic instruments, the cannula tip should be >12 cm from the surgical target to permit proximal joint passing the cannula tip and articulating. Using this glove-port and making the cannula tip to be outside of the abdominal cavity, we were able to secure the distance to the surgical target, especially for lymphadenectomy around the central vessels under trans-umbilical port placement, thus maximizing the cosmetic effect.

In the present report, the dVSP demonstrated favorable performance compared with positive aspect of single-incision laparoscopic surgery and robot surgery. There was minimal collision among instruments and endoscope compared to single-incision laparoscopic surgery while maintaining the advantages of robotic surgery such as better three-dimensional view, dexterity, and ergonomics. The peri- and postoperative results were also favorable. Considering its initial application for right hemicolectomy, the operation time was acceptable. Free location of robotic cart around operating table could be an advantage to shorten the docking time compared to previous robotic system models which required fixed location and angle to the operating table. Estimated blood loss during surgery and duration of postoperative hospital stay, time to first flatus and soft diet was comparable to previous reports of laparoscopic or robotic colorectal surgery.57 Regarding pathologic outcomes, the number of retrieved lymph nodes and status of resection margin were acceptable. The cosmetic result was satisfactory with a transumbilical incision, which was essential to extract the surgical specimen for colorectal surgery and visible scarring was minimal.

In summery, the dVSP is feasible and safe to perform single-incision robotic right hemicolectomy. It can maximize cosmetic effect while maintaining surgical principle of right hemicolectomy. Accumulation of data might confirm the validity of this surgical platform.

Supplementary Information

AUTHORS’ CONTRIBUTIONS

Conceptualization: GRN, GHK. Formal analysis: GTN, MHH, SSC, RAL, KHK. Methodology: GTN, MHH, SSC, RAL, KHK. Writing-original draft: GTN, KHK. Writing-review and editing: GTN, SSC, RAL, KHK.

CONFLICT OF INTEREST

None.

FUNDING

None.

ACKNOWLEDGMENTS

None.

References

  1. Weber PA, Merola S, Wasielewski A, Ballantyne GH. Telerobotic-assisted laparoscopic right and sigmoid colectomies for benign disease. Dis Colon Rectum 2002;45:1689-1696.
    Pubmed CrossRef
  2. Balch GC. Emerging role of laparoscopic and robotic surgery for rectal cancers. Ann Surg Oncol 2009;16:1451-1453.
    Pubmed CrossRef
  3. Pigazzi A, Garcia-Aguilar J. Robotic colorectal surgery: for whom and for what?. Dis Colon Rectum 2010;53:969-970.
    Pubmed CrossRef
  4. Rashid TG, Kini M, Ind TEJ. Comparing the learning curve for robotically assisted and straight stick laparoscopic procedures in surgical novices. Int J Med Robot 2010;6:306-310.
    Pubmed CrossRef
  5. Rondelli F, Balzarotti R, Villa F, et al. Is robot-assisted laparoscopic right colectomy more effective than the conventional laparoscopic procedure? A meta-analysis of short-term outcomes. Int J Surg 2015;18:75-82.
    Pubmed CrossRef
  6. Kim MJ, Park SC, Park JW, et al. Robot-assisted Versus Laparoscopic Surgery for Rectal Cancer: A Phase II Open Label Prospective Randomized Controlled Trial. Ann Surg 2018;267:243-251.
    Pubmed CrossRef
  7. Park EJ, Cho MS, Baek SJ, et al. Long-term oncologic outcomes of robotic low anterior resection for rectal cancer: a comparative study with laparoscopic surgery. Ann Surg 2015;261:129-137.
    Pubmed CrossRef

Supplementary File

Metrics for This Article

Share this article on

  • kakao talk
  • line

Related articles in JMIS

Journal of Minimally Invasive Surgery

pISSN 2234-778X
eISSN 2234-5248